IPSentry Version 4

Home |   help index | Screen Shot

Related Topics Screen Shots Email to support@ipsentry.com Go to ipsentry.com

IPSentry - Server Settings - Add-Ins


After selecting "Add-In" on the left side of the "Server Settings" tab, you will have access to the following fields for selection and configuration of installed IPSentry Add-In components. 

Please see the How-To section for additional information on various configurations.

Name
Select a short yet meaningful name to describe this monitor entry.  The name must be unique in order to identify this configuration from any other. 

Also note that when IPSentry cycles through these items, the devices are ordered alphabetically.  Dependent machines are ordered within their respective parent machines.  Therefore, a system named AROUTER will be checked before an item named CROUTER.

Description
Use this field to further describe this monitoring entry.  A brief description of the unit, device, etc.  In many cases, this can be the same as the name however it can be better used for various identification purposes.  This field must contain a value even though the value is used only for various 'display' operations.

Add-In
This field represents the stored name of the Add-In and is read-only (you can not and should not edit this value).  The value placed in this field is the name of the add-in selected after choosing "Browse Add-Ins".

Add-In Configuration (button)
If the add-in provides a configuration interface (as of this writing, all add-ins provided by RGE, Inc. utilize a configuration interface), this option will launch the configuration editor for that specific Add-In.  You should refer to your Add-In documentation for information on whether the add-in supports Monitor Configuration.

Note: Do NOT hit this button before selecting an add-in using the "Browse Add-Ins" button.  You will receive a "Control Creation" error if the add-in has not been selected.

Browse Add-Ins
This button will load a list of available Monitor type Add-Ins from which you can select the add-in you wish to use.  Unlike the image below, only Add-Ins with a usage type of "mon" (monitor) will be available.

Note: Some add-ins are Alert Only or Menu Only type add-ins and they will not appear in the list of add-ins available at this point.

Add-In Args
Add-In's may or may not accept "args" through the IPSentry Add-In Interface.   Check your Add-In documentation for the format and content you should put in this field.  This will vary between add-ins as much as command line argument vary from application to application.

As you will notice with many add-ins, the contents of this field very often resembles a command line.

With add-ins that provide a configuration interface, you will seldom have need to modify the contents of this field.  As a matter of fact, if this field is edited incorrectly, the add-in may not function.  We recommend using the "Add-In Configuration" button for all add-in configuration options.  Again, check the documentation provided with the add-in component.

COMMON TO ALL MONITORING TYPES

Schedule (Button)
This will bring up the IPSentry Down-Time Scheduling tool and allow you to specify what times during which days that this entry should or should not be monitored.   
(See Down-Time Scheduling )

Reverse Alert
In some cases, you may find it necessary to be notified when a server or network device is available as opposed to unavailable. (I.e. Specific DHCP lease activated, or a backup system has been enabled).  By selecting this option, a successful attempt on the device will trigger the alerts and a failure will simply continue on to the next monitored device.

Suspend Sentry
Select this option to suspend this monitoring option indefinitely.  No monitoring or alerting will be performed on this entry until the suspend flag has been removed.  You can easily identify suspended machines in the item list as identified by the yellow triangular warning icon.

In version 4.6.55 and later, you are not prompted for the duration in Days:Hours:Minutes.  The release date/time is calculated from the moment you hit "OK".  Leaving the field blank or entering 0:0:0 will suspend the item indefinitely.

Poll Frequency
Some systems require a more or less frequent monitoring.  In order to decrease network overhead, you scan select to have IPSentry skip a monitoring entry for the defined number of cycles.

For example: If you enter a value of 5 in this field, IPSentry will have to perform 5 full monitoring cycles before this entry will be monitored once.  If you have your Sentry Cycle Interval set to 5, that would be a minimum of once very 5*5 or 25 minutes.  Then, you must add-in the amount of time consumed to complete an entire cycle and multiply that times this value.

Depends On
Provides a list of existing monitoring entries from which you may select one that MUST be available (successful) before the current entry will be checked.  For Example:  If Web1 is on the other side of Router1, there is no need to check Web1 if Router1 is down.   While editing the Web1 configuration, you would select Router1 for this field.  This would cause Web1 to be skipped whenever there is a failure at Router1.

Sync Failure Count
Checking this option keeps the Attempt + Failure counters synchronized among dependents of specific machines.  If the entry on which this item depends is in a failure status, this item will be skipped yet the failure counters will be incremented.

Example: If Web1 Depends on Router1 and Router1 fails, Web1 will also show as a failure thereby reducing the up-time percentage.

Current Dependents
This area lists all the monitoring entries that depend on the success of this machine whether directly, or indirectly through another machine.  This area provides a basic tree-view of dependency information for the given device.

Add (button)
Use this option to quickly add direct dependents to this device by selecting the entries from a list presented after clicking this button.  Simply check the items that will depend on the current machine and click OK.

Remove (button)
Use this option to quickly remove the selected dependent from this device.  Simply highlight the dependent that should no longer depend on the current device and hit the Remove button.

Copy From (button)
This option loads a list of machines from which you can copy the entire configuration.  Very handy when you have several entries to create that are all relatively similar in function (i.e. Adding 10 web servers where the only difference is the IP Address, adding 25 routers with only the IP Address being different.) (See Copy From )

Order Alerts (button)
When you hit this button, you will be presented with the list of alerts in the order in which they will be triggered.  In some cases, you may want to have fast alerts such as Email, Syslog, Launch, executed before the pager alerts.  In other cases, you may want pager alerts to be the first alert triggered.    Use this option to order the alerts to meet your specific needs. (See Ordering Alerts)

Test (button)
This button simply tests the device monitoring configuration as entered.  You will either receive a "Sentry OK" response if no alerts would be triggered based on the result of the test, or you will receive a "Failed" message noting that in live operation, any configured alerts would have been triggered.

This allows you test a known 'good' system to ensure that your settings are correct.

 


Related Topics Related Topics


SCREEN SAMPLES
Click on a field or area for details.

Home  |  Product Info  |  Download  |  Pricing  |  Order Now   |  Support  |  Contact Us

Contact: support@ipsentry.com  https://ipsentry.com © 2006 by RGE, Inc. - All Rights Reserved